Non-fluorocarbon Series Slim & Short type (200-240VAC)
New release on April 22, 2026!
No obligatory inspection by Japanese law required.
Compact and lightweight body allows to install in a narrow space.
No obligatory inspection by Japanese law required.
Compact and lightweight body allows to install in a narrow space.

Features
| Type of mounting | Environment | Cooling method | Functions | Obligatory inspection by Japanese law | |||
| Rececced *H350BCS only |
Duct kit (Option) | Adjustable louver (Accessory) *Except H300BCS |
Indoor | Compressor | Energy-saving mode | Display | N/A |
Certificates/Approvals
| EU RoHS2 | China RoHS | TSCA | CE | UL | CSA | PSE |
Model/Specification
| Model | OCA- H350BCS-AW2 |
OCA- H550BCS-AW2 |
OCA- H1100BCS-AW2 |
|
| Type of mounting | Lateral mounting | |||
| Cooling capacity ※1 | 320/350W | 500/540W | 1000/1100W | |
| Rated voltage (50/60Hz)※2 |
Single phase 200-240VAC | |||
| Rated current consumption ※3 |
200V | 1.1/1.4A | 1.2/1.5A | 2.2/2.6A |
| 220V | 1.2/1.4A | 1.3/1.6A | 2.3/2.6A | |
| 240V | 1.3/1.4A | 1.5/1.6A | 2.6/2.6A | |
| Max. current consumption※3 | 1.5/1.7A | 1.8/1.9A | 3.2/3.5A | |
| Starting current | 4.8/4.3A | 4.8/4.9A | 11.4/11.3A | |
| Rated power consumption ※3 |
200V | 200/240W | 220/270W | 400/440W |
| 220V | 230/270W | 260/300W | 460/480W | |
| 240V | 270/290W | 310/340W | 560/520W | |
| Max.power consumption※3 | 350/370W | 400/430W | 740/730W | |
| Working temperature ※4 | +20 to+55℃ | |||
| Working humidity | Not exceeding 85%RH, free from condensation | |||
| Noise (Charactristic A) |
58dB(A) | 59dB(A) | 61dB(A) | |
| Temp.setting range ※4 | +30 to+45℃ (Initial setting +35℃) | |||
| Display | Innter temperature/Alarm code/Operation lamp(Green)/Alarm lamp(Red) | |||
| Function | Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder,Forced cooling operation for inspection |
|||
| Alarm output | No-voltage contact output 1a x 2 (COMMON) 250VAC 2A 30VDC 2A | |||
| Communication function | RS485 2-wire system (Modbus RTU) | |||
| Vibration withstand | Vibration frequency10 to 55Hz, Amplitude 0.15mm, Sweep cycle 10 times | |||
| Protection category | Internal circuit IP54 equivalent | |||
| Conformity of standards | Environment | RoHS2 , TSCA | ||
| Refrigerant | R1234yf (130g) |
R1234yf (170g) |
R1234yf (340g) |
|
| GWP※5 | <1 | |||
| Color | Powder coating N8 corresponding, N4 corresponding | |||
| Dimensions(mm) | W200×H590×D200 | W350×H450×D215 | W300×H730×D230 | |
| Weight | 15kg | 18kg | 25kg | |
Contents of page
OCA-H350BCS-AW2

Cooling capacity
320/350W(50/60Hz)
A complete set of supply
●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs
●Nut:6 pcs ●Packing:1 roll (4m) ●Drain hose:1 pc(2m)
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy
●Nut:6 pcs ●Packing:1 roll (4m) ●Drain hose:1 pc(2m)
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy
Consumable parts
| Replacement fan | Replacement filter | |
| Internal fan model | FM-11938P-AW-01 | CF-S1(2pcs/set) |
| External fan model | FM-15038M-AW230-00 | |
Performance diagram
- Click the image to see a larger version.
- Please refer to "Model Selection for enclosure cooler" when you see the performance diagram.

Cooling capacity
500/540W(50/60Hz)
A complete set of supply
●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs
●Nut:6 pcs ●Packing:1 roll (4m) ●Drain hose:1 pc(2m)
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy
●Adjustable louver:1 pc ●Screws for louver:4 pcs
●Nut:6 pcs ●Packing:1 roll (4m) ●Drain hose:1 pc(2m)
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy
●Adjustable louver:1 pc ●Screws for louver:4 pcs
Consumable parts
| Replacement fan | Replacement filter | |
| Internal fan model | FM-15038P-AW230-00 | CF-S1(2pcs/set) |
| External fan model | FM-15038M-AW230-00 | |
Performance diagram

- Click the image to see a larger version.
- Please refer to "Model Selection for enclosure cooler" when you see the performance diagram.

Cooling capacity
1000/1100W(50/60Hz)
A complete set of supply
●COOLCABI:1 pc ●Fixing bolt:6 pcs ●Washer:6 pcs ●Spring washer:6 pcs
●Nut:6 pcs ●Packing:1 roll (4m) ●Drain hose:1 pc(2m)
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy
●Adjustable louver:1 pc ●Screws for louver:4 pcs
●Nut:6 pcs ●Packing:1 roll (4m) ●Drain hose:1 pc(2m)
●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy
●Adjustable louver:1 pc ●Screws for louver:4 pcs
Consumable parts
| Replacement fan | Replacement filter | |
| Internal fan model | FM-15038P-AW230-00 | CF-S10(2pcs/set) |
| External fan model | FM-15038M-AW230-00 | |
Performance diagram

- Click the image to see a larger version.
- Please refer to "Model Selection for enclosure cooler" when you see the performance diagram.
Cautions
・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
・Failure to this may degrade cooling performance of the unit and cause condensation.
・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
・Electrical connection should be made via appropriate circuit breakers.
・Do not use this product in the following places.
-A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs.
-A place where the product may be subject to shock or vibration.
・Make sure that electrical wiring work is done by qualified electrician.
・Check for damage on packaging when the product is delivered.
・Any packaging damage may be a cause of malfunction.Make sure that the packaging is not damaged on delivery and contact your supplier.
・Failure to this may degrade cooling performance of the unit and cause condensation.
・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
・Electrical connection should be made via appropriate circuit breakers.
・Do not use this product in the following places.
-A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs.
-A place where the product may be subject to shock or vibration.
・Make sure that electrical wiring work is done by qualified electrician.
・Check for damage on packaging when the product is delivered.
・Any packaging damage may be a cause of malfunction.Make sure that the packaging is not damaged on delivery and contact your supplier.