Features

Type Specifications
Non-filter Energy saving Max. suction air temp. 80℃ Top-runner motor High collection efficiency

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE

Quick Selection

Model/Specifications

Model OMC-
N205
OMC-
N205H
OMC-
N210
OMC-
N210H
OMC-
N215
OMC-
N215H
OMC-
N225
OMC-
N225H
Max. air flow *1 4.5/5.0m3/min 8.0/10.0m3/min 14.5/16.5m3/min 21.5/24.5m3/min
Max. static pressure *1 0.59/0.85kPa 1.13/1.55kPa 1.57/2.17kPa 1.88/2.57kPa
Collection efficiency Min. 99%
Particle diameter 2µm or larger 1µm or larger 2µm or larger 1µm or larger 2µm or larger 1µm or larger 2µm or larger 1µm or larger
Rated voltage 3-phase, 200VAC 50Hz/ 200 ‒ 220VAC 60Hz
Rated motor output 0.4kW(2P) 0.75kW(2P) 1.5kW(2P) 2.2kW(2P)
Motor efficiency*2 76.0/76.0-77.0% 81.5/81.1-82.5%
IE3/IE3-IE3
85.8/85.6-86.0%
IE3/IE3-IE3
86.0/86.8-86.9%
IE3/IE3-IE3
Rated current consumption *1 1.9/1.7-1.7A 4.0/3.9-3.6A 7.1/7.1-6.4A 9.5/9.3-8.4A
Working temperature 0 to +40℃
Working humidity Max. 85%RH, free from condensation
Noise 66/70dB(A) 70/74dB(A) 72/76dB(A) 74/78dB(A)
Max. suction air temp. +80℃
Environmental standard RoHS2
Suction port diameter Ø98mm Ø123mm Ø148mm Ø198mm
Color Powder coating : Ivory (10GY9/1 equivalent), Light green (10GY8/4 equivalent)
Weight 25.0kg 40.0kg 57.0kg 68.0kg
Drain port Ø31 pipe
*1. Rated value at the time of the ambient air temperature of 25℃
*2. Efficiency value of the motor unit.

Structure

Original technology enabled high collection rate with no filter

構造

Mechanism

メカニズム

  1. Oil mist flows along the impinging plate. At the primary treatment part, cutting dust and large particles are removed.
  2. Turbo fan accelerates the air speed to blow it in the centrifugal direction to let the oil particles
    hit against the collection unit.
  3. Oil particles caught by the collection unit are gathered on the inner wall by centrifugal force to be discharged from the drain port in the form of liquid.
  4. Clean air goes out.

Primary treatment using inertial collision and centrifugal force

Collection unit with ultimate level of colliding force

一次処理部

Incoming air hits against the Impinging plate and then rotates along the inner wall of the primary treatment part. Large particles and dust are separated from the air during this process.

捕集ユニット

The collection unit causes more oil particles to collide to achieve higher collection efficiency. OMC-N2**H models lead the non-filter oil mist collectors in collection rate by its optimized design.

Maintenance

ドライバーでネジを外す。

1. Remove the screw using a screwdriver.

キャッチクリップ2ヵ所を外し 扉を開く。

2. Unlock the two draw latches to open the Access Door.

捕集ユニットの留め金具を外す。

3. Unfix the Collection unit by turning the four locks.

Take out the Collection unit to clean.

4. Take out the Collection unit to clean.

メンテナンス

Access Door can be opened from either side.


Product lineup

OMC-N205(H)

OMC-N205

Max. air flow

4.5/5m3/min

A complete set of supply

Oil Mist Collector : 1 unit Ø32Drain hose : 2m long Drain hose band : 1 pc. 
Anti-vibration rubber : 4 pcs. Maintenance sticker : 1 sheet Instruction manual : 1 copy

Collection efficiency

Test oil : Water-insoluble cutting oil
Measuring instrument : Low volume air sampler type AN-200

捕集率

Dimensional drawing

外形寸法図

Mounting hole processing

取付穴加工図

Anti-vibration rubber (accessory)

防振ゴム


OMC-N210(H)

OMC-N210

Max. air flow

8/10m3/min

A complete set of supply

Oil Mist Collector : 1 unit Ø32 Drain hose : 2m long Drain hose band : 1 pc. 
Anti-vibration rubber : 4 pcs. Maintenance sticker : 1 sheet Instruction manual : 1 copy

Collection efficiency

Test oil : Water-insoluble cutting oil
Measuring instrument : Low volume air sampler type AN-200

捕集率

Dimensional drawing

外形寸法図

Mounting hole processing

取付穴加工図

Anti-vibration rubber (accessory)

防振ゴム


OMC-N215(H)

OMC-N215

Max. air flow

14.5/16.5m3/min

A complete set of supply

Oil Mist Collector : 1 unit Ø32 Drain hose : 2m long Drain hose band : 1 pc. 
Anti-vibration rubber : 4 pcs. Maintenance sticker : 1 sheet Instruction manual : 1 copy

Collection efficiency

Test oil : Water-insoluble cutting oil
Measuring instrument : Low volume air sampler type AN-200

捕集率

Dimensional drawing

外形寸法図

Mounting hole processing

取付穴加工図

Anti-vibration rubber (accessory)

防振ゴム


OMC-N225(H)

OMC-N225

Max. air flow

21.5/24.5m3/min

A complete set of supply

Oil Mist Collector : 1 unit Ø32 Drain hose : 2m long Drain hose band : 1 pc. 
Anti-vibration rubber : 4 pcs. Maintenance sticker : 1 sheet Instruction manual : 1 copy

Collection efficiency

Test oil : Water-insoluble cutting oil
Measuring instrument : Low volume air sampler type AN-200

捕集率

Dimensional drawing

外形寸法図

Mounting hole processing

取付穴加工図

Anti-vibration rubber (accessory)

防振ゴム


Option

Auto-cleaning unit

自動洗浄ユニット

Eliminates frequent servicing of OMC-N2 units. Cleans MISTCATCH with compressed air and water.

Optional parts for OMC-N2

オプション品

Duct flange, Duct hose, Silencer, Mounting stand, etc.

Cautions

・This product is intended for collecting general watersoluble and oil mist that generates during production process using various machine tools. Never have it inhale the following substances.
 - Ignition sources and fire sparks generated in machine processing,
 - Flammable substances such as gasoline, thinner, benzin, kerosene and others as well as oil and cleaning liquid with an ignition point 80 degrees C or below,
 - Explosive substances such as aluminium, magnesium and titan as well as materials ridden with those substances,
 - Flammable liquid, mist and materials ridden with these substances,
 - Corrosive and adhesive substances and hazardous gas or air with a lot of unusual substances
 - Large amount of dust or cutting chips
 - Hot air exceeding 80 deg. C.
 - Large amount of liquid,
 - Substances that remarkably accelerate rusting of metals or aging of plastics

・This product should not be used in an atmosphere which contains chlorine, sulfuric or fluorine gasses, oxalic acid, xylene, or methyl tetrachloride and the like.
・Do not use this product in a corrosive atmosphere.
・Tampering or repairing the product should be strictly avoided. Please contact us for repairing service.
・Do not operate the product with its terminal box uncovered.
・Never touch the motor while the unit is in operation. Do not put your fingers or foreign matters into the rotating part of Turbo Fan.
・Indoor use only. The altitude of the site of use should be lower than 1000 m.
・The site of use should be free from vibration or impact.
・Make sure that the packaging is not damaged on delivery.
・Use this product within the temperature range from 0℃ to +40℃ and humidity not exceeding 85%RH (no condensation).
・Impact, vibration or excess load should be avoided during transportation.
・Precision apparatuses should not be arranged near the exhaust port where fine particles may fall on.