Go to global navigation

Read the article

Go to local navigation

Go to footer



Climate control equipment

Home > Climate control equipment > Indoor enclosure cooler "COOLCABI" lineup > Non-fluorocarbon Series Standard type Roof mounting

Non-fluorocarbon Series Standard type Roof mounting


No obligatory inspection by Japanese law required.
Rich lineup in roof mounting type.

COOLCABI ノンフロンシリーズ

Features

Type of mounting Environment Cooling method Functions Obligatory inspection by Japanese law
Duct kit (Option) Adjustable louver (Option) Indoor Compressor Energy-saving mode Display N/A

Certificates/Approvals

EU RoHS2 China RoHS CE UL CSA PSE

Quick Selection

Model/Specification

Model OCA-
H300AC-A200
OCA-
H700AC-A200
OCA-
H1100AC-A200
OCA-
H1700AC-A200
OCA-
H2300AC-A200
OCA-
H3000AC-A200
Type of mounting Roof mounting
Cooling capacity *1 300/350W 600/700W 950/1100W 1550/1700W 2100/2300W 2700/3000W
Rated voltage(50/60Hz) Single phase 200VAC Three phase 200VAC
Current consumption *2 Rated 1.4/1.2A 2.1/2.1A 3.3/3.2A 3.9/4.0A 3.4/3.6A 5.0/5.5A
Max. 1.5/1.4A 2.5/2.6A 3.8/3.8A 4.4/4.8A 3.9/4.2A 5.9/7.0A
Starting current 3.8/3.6A 6.7/6.0A 13.1/12.1A 15.0/13.9A 14.8/15.5A 18.9/20.4A
Power consumption *2 Rated 230/230W 400/410W 580/640W 710/790W 940/1100W 1430/1710W
Max. 260/280W 490/510W 690/760W 830/950W 1130/1320W 1780/2220W
Comp. motor output 100W 275W 375W 525W 850W 1300W
Working temperature*3 +20 to+50℃
Working humidity Not exceeding 85%RH,free from condensation
Noise(Charactristic A) 61dB(A)
Temp. setting range *3 +30 to+45℃ (Initial setting:+35℃)
Display Innter temperature/Alarm code/Operation lamp/Alarm lamp
Functions Off-temperature alarm, Detection of abnormal heat dissipation, Detection of temperature sensor disconnection, Maintenance reminder, Forced cooling operation for inspection,Detection of drain overflows, Detection of evaporator ice-up
External output Alarm output 1a 240V 1.5A×2(COMMON)
Vibration withstand Vibration frequency 10 to 55Hz,Amplitude 0.15mm, Sweep cycle 10 times
Protection category *4 Internal circuit IP54 equivalent
Conformity to standards EMC Directive EN61000-6-2, EN61000-6-4 complaint
LV directive EN60335-1,EN60335-2-40,EN62233
Environment RoHS2
Refrigerant R1234yf
(140g)
R1234yf
(190g)
R1234yf
(410g)
R1234yf
(500g)
R1234yf
(580g)
R1234yf
(1580g)
GWP *5 <1
Color Powder coating N8 corresponding, N4 corresponding
Dimensions(mm) W454×H230
×D253
W551×H330
×D273
W603×H349
×D355
W596×H446
×D353
W655×H444
×D403
W765×H444
×D403
Weight 16.0kg 23.5kg 33.0kg 37.0kg 47.0kg 57.0kg
*1 Nominal value when both of internal and external temperatures are +35℃.
*2 Nominal values at 35℃ temperature both inside and outside are indicated in “Rated” and values at 50℃ outside and 35℃ inside are indicated in “Max”.
*3 Use only within the specified temperature range.
*4 Excl. drain pipe
*5 By IPCC 5th Report 2013


Product lineup

OCA-H300AC-A200

OCA-H300AC-A200

Cooling capacity

300/350W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc.(5m) ●L joint:2 pcs ●Terminal board:1 pc. 
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-11938P-A200-00 CF-S1(2pcs/set)
External fan model FM-15038M-A200-00

Performance diagram

能力グラフ

Dimensional drawing

外形寸法図

Mounting cutout

パネルカット図


OCA-H700AC-A200

OCA-H700AC-A200

Cooling capacity

600/700W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc.(5m) ●L joint: 2pcs ●Terminal board:1 pc 
●Pcaking:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-15038M-A200-00 CF-S1(2pcs/set)
External fan model FM-15038M-A200-00

Performance diagram

能力グラフ

Dimensional drawing

外形寸法図

Mounting cutout

パネルカット図


OCA-H1100AC-A200

OCA-H1100AC-A200

Cooling capacity

950/1100W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs  ●Drain hose:1 pc.(5m) ●L joint:2 pcs ●Terminal board:1 pc
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-15038P-A200-00 CF-S2(2pcs/set)
External fan model FM-15038M-A200-00

Performance diagram

能力グラフ

Dimensional drawing

外形寸法図

Mounting cutout

パネルカット図


OCA-H1700AC-A200

OCA-H1700AC-A200

Cooling capacity

1550/1700W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt: 4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc.(5m) ●L joint:2 pcs ●Terminal board:1 pc 
●Packing: 1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-15038P-A200-00 CF-S4(2 pcs/set)
External fan model FM-15038M-A200-00

Performance diagram

能力グラフ

Dimensional drawing

外形寸法図

Mounting cutout

パネルカット図


OCA-H2300AC-A200

OCA-H2300AC-A200

Cooling capacity

2100/2300W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc.(5m) ●L joint:2 pcs ●Terminal board:1 pc. 
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacement fan Replacement filter
Internal fan model FM-15038P-A200-00 CF-S5(2 pcs/set)
External fan model FM-15038M-A200-00

Performance diagram

能力グラフ

Dimensional drawing

外形寸法図

Mounting cutout

パネルカット図


OCA-H3000AC-A200

OCA-H3000AC-A200

Cooling capacity

2700/3000W(50/60Hz)

A complete set of supply

●COOLCABI:1 pc. ●Fixing bolt:4 pcs ●Washer:4 pcs ●Spring washer:4 pcs 
●Nut:4 pcs ●Drain hose:1 pc.(5m) ●L joint:2 pcs ●Terminal board:1 pc. 
●Packing:1 pc ●Alarm explanation sheet:1 sheet ●Instruction manual:1 copy

Consumable parts

Replacemente fam replacement filter
Internal fan model FM-15038P-A200-00 CF-S6(2 pcs/set)
External fan model FM-15038M-A200-00

Performance diagram

能力グラフ

Dimensional drawing

外形寸法図

Mounting cutout

パネルカット図


Option/Related products

Adjustable louver set

Cool air is directly blown to the heat source to prevent local temperature rise as well as creating uniform temperature in the enclosure.

Duct kit

Use of Duct kit allows cooling from a separately-placed COOLCABI.

Drain evaporator

Free from troublesome drain treatment and no more drain worrying about drainage problem.

Cautions

・Locate the unit so as to assure good ventilation and distance of at least 200mm from the walls or other units.
・Failure to this may degrade cooling performance of the unit and cause condensation.
・Setting temperature should be basically at 35℃. Avoid setting at an unnecessarily low value.
・Electrical connection should be made via appropriate circuit breakers.
・Do not use this product in the following places.
 --A place where corrosive or flammable gases exist in the air, or where the insulation destruction occurs
 --A place where the product may be subject to shock or vibration.
・Make sure that electrical wiring work is done by qualified electrician.
・Check for damage on packaging when the product is delivered.
・Any packaging damage may be a cause of malfunction. Make sure that the packaging is not damaged on delivery and contact your supplier.